Dec 2021
Heads were thoroughly cleaned, deburred gasket faces and readied.
In the pic, guides were sized checked. Head heated to 100°C, guides chilled in freezer. Teflon paste by Loctite was used to help lube the fit and to seal guide-to-head. Notice thermocouple sits in oil channel for measuring temperature.
Pen points to raw edge which was carefully rounded with a bit of wet&dry paper. Tickling this simply aids installation.